Analytical reproducibility evaluated from duplicate measurements of authentic ante- and postmortem blood samples by LC–MS/MS compared with long-term imprecision estimates from quality control samples

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Analytical reproducibility evaluated from duplicate measurements of authentic ante- and postmortem blood samples by LC–MS/MS compared with long-term imprecision estimates from quality control samples. / Hansen, Stine Lund; Linnet, Kristian; Rasmussen, Brian Schou.

I: Forensic Science International, Bind 339, 111415, 2022.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Hansen, SL, Linnet, K & Rasmussen, BS 2022, 'Analytical reproducibility evaluated from duplicate measurements of authentic ante- and postmortem blood samples by LC–MS/MS compared with long-term imprecision estimates from quality control samples', Forensic Science International, bind 339, 111415. https://doi.org/10.1016/j.forsciint.2022.111415

APA

Hansen, S. L., Linnet, K., & Rasmussen, B. S. (2022). Analytical reproducibility evaluated from duplicate measurements of authentic ante- and postmortem blood samples by LC–MS/MS compared with long-term imprecision estimates from quality control samples. Forensic Science International, 339, [111415]. https://doi.org/10.1016/j.forsciint.2022.111415

Vancouver

Hansen SL, Linnet K, Rasmussen BS. Analytical reproducibility evaluated from duplicate measurements of authentic ante- and postmortem blood samples by LC–MS/MS compared with long-term imprecision estimates from quality control samples. Forensic Science International. 2022;339. 111415. https://doi.org/10.1016/j.forsciint.2022.111415

Author

Hansen, Stine Lund ; Linnet, Kristian ; Rasmussen, Brian Schou. / Analytical reproducibility evaluated from duplicate measurements of authentic ante- and postmortem blood samples by LC–MS/MS compared with long-term imprecision estimates from quality control samples. I: Forensic Science International. 2022 ; Bind 339.

Bibtex

@article{96b8383730f84acfbf78079df0c7a52b,
title = "Analytical reproducibility evaluated from duplicate measurements of authentic ante- and postmortem blood samples by LC–MS/MS compared with long-term imprecision estimates from quality control samples",
abstract = "Precision (or imprecision) is one of the central performance parameters of all analytical methods. It is often evaluated during method validation in spiked samples, with a relatively low number of measurements typically during a short period. Validation results are well documented in the literature; however, evaluation of imprecision in authentic cases compared with long-term imprecision from quality control samples has not often been reported on. The aim of this study was to investigate imprecision estimated from duplicate measurements of ante- and postmortem blood samples and long-term imprecision estimates from quality control samples and to compare variations between them. Data were analyzed by using robust statistics, where results for the 29 analytes most frequently quantified by liquid chromatography–tandem mass spectrometry in ante- and postmortem blood samples were included. A total of 41,460 positive findings in authentic whole blood and 51,522 measurements from quality controls were investigated. Analysis was performed in duplicate on independent batches on two separate days. Overall, the imprecision estimated in quality control and the authentic samples were akin for most analytes. Ante- and postmortem blood samples showed similar imprecision for the majority of the analytes and were approximately the same level as long-term imprecision estimated from the quality control samples at low level, whereas relative imprecision of the quality control samples at high level were slightly lower than ante- and postmortem blood samples. The methods we evaluated showed satisfactory reproducibility and robustness for the investigated analytes.",
author = "Hansen, {Stine Lund} and Kristian Linnet and Rasmussen, {Brian Schou}",
year = "2022",
doi = "10.1016/j.forsciint.2022.111415",
language = "Dansk",
volume = "339",
journal = "Forensic Science International",
issn = "0379-0738",
publisher = "Elsevier Ireland Ltd",

}

RIS

TY - JOUR

T1 - Analytical reproducibility evaluated from duplicate measurements of authentic ante- and postmortem blood samples by LC–MS/MS compared with long-term imprecision estimates from quality control samples

AU - Hansen, Stine Lund

AU - Linnet, Kristian

AU - Rasmussen, Brian Schou

PY - 2022

Y1 - 2022

N2 - Precision (or imprecision) is one of the central performance parameters of all analytical methods. It is often evaluated during method validation in spiked samples, with a relatively low number of measurements typically during a short period. Validation results are well documented in the literature; however, evaluation of imprecision in authentic cases compared with long-term imprecision from quality control samples has not often been reported on. The aim of this study was to investigate imprecision estimated from duplicate measurements of ante- and postmortem blood samples and long-term imprecision estimates from quality control samples and to compare variations between them. Data were analyzed by using robust statistics, where results for the 29 analytes most frequently quantified by liquid chromatography–tandem mass spectrometry in ante- and postmortem blood samples were included. A total of 41,460 positive findings in authentic whole blood and 51,522 measurements from quality controls were investigated. Analysis was performed in duplicate on independent batches on two separate days. Overall, the imprecision estimated in quality control and the authentic samples were akin for most analytes. Ante- and postmortem blood samples showed similar imprecision for the majority of the analytes and were approximately the same level as long-term imprecision estimated from the quality control samples at low level, whereas relative imprecision of the quality control samples at high level were slightly lower than ante- and postmortem blood samples. The methods we evaluated showed satisfactory reproducibility and robustness for the investigated analytes.

AB - Precision (or imprecision) is one of the central performance parameters of all analytical methods. It is often evaluated during method validation in spiked samples, with a relatively low number of measurements typically during a short period. Validation results are well documented in the literature; however, evaluation of imprecision in authentic cases compared with long-term imprecision from quality control samples has not often been reported on. The aim of this study was to investigate imprecision estimated from duplicate measurements of ante- and postmortem blood samples and long-term imprecision estimates from quality control samples and to compare variations between them. Data were analyzed by using robust statistics, where results for the 29 analytes most frequently quantified by liquid chromatography–tandem mass spectrometry in ante- and postmortem blood samples were included. A total of 41,460 positive findings in authentic whole blood and 51,522 measurements from quality controls were investigated. Analysis was performed in duplicate on independent batches on two separate days. Overall, the imprecision estimated in quality control and the authentic samples were akin for most analytes. Ante- and postmortem blood samples showed similar imprecision for the majority of the analytes and were approximately the same level as long-term imprecision estimated from the quality control samples at low level, whereas relative imprecision of the quality control samples at high level were slightly lower than ante- and postmortem blood samples. The methods we evaluated showed satisfactory reproducibility and robustness for the investigated analytes.

U2 - 10.1016/j.forsciint.2022.111415

DO - 10.1016/j.forsciint.2022.111415

M3 - Tidsskriftartikel

C2 - 35952616

VL - 339

JO - Forensic Science International

JF - Forensic Science International

SN - 0379-0738

M1 - 111415

ER -

ID: 319169861